Hot line:
+86 18898580427
ADSS Double Jacket

ADSS Double Layer All-Dielectric Cable For 100-400M Span

Characteristics of ADSS:
Light weight, small cable diameter, reducing the ice;
Can be continuously electric erection;
Using AT sheath, large span

Description:
ADSS Double Layer Cable is used  for communication cable of overhead high-voltage electricity transmission system,also can be used at the areas where lighting is frequent or distance is big. Aramid yarn is used as the strength member to assure the tensile and strain Performance.Mainly installed at existing 220kV or lower voltage power lines . Two Jacket and stranded loose tube design

According to different Related Strength Tension which suitable different situation. Please check the Cable Performance Parameter according to the 10-30 KN.

Cable Performance Parameter

Span meter

200

300

400

Related Strength Tension(RTS)

17.5 kn

20.6 kn

28 kn

Max Allowable Tension(MAT)

6.9 kn

8.2 kn

11.5 kn

Average Annual Operation Tension(EDS)

4.36 kn

5.17 kn

7.0 kn

Young Modulus

14.1 kn/mm2

15.2 kn/mm2

19.3 kn/mm2

Coefficient of Thermal Expansion

4.4  10-6/℃

3.1 10-6/℃

2.4 0-6/℃

Allowable Crush Resistance

Long Term: 1100     n/100mm

Long Term: 1100     n/100mm

Long Term: 1100     n/100mm

 

Short Term: 2200     n/100mm

Short Term: 2200     n/100mm

Short Term: 2200     n/100mm

Minimum Bending Radius

Operating: 220 mm

Operating: 220 mm

Operating: 220 mm

 

Installlation: 360 mm

Installlation: 360 mm

Installlation: 360 mm

Temperature Range

Operating:  -40∽ +70℃

Operating:  -40∽ +70℃

Operating:  -40∽ +70℃

 

Installlation:  -15∽ +60℃

Installlation:  -15∽ +60℃

Installlation:  -15∽ +60℃

Out Sheath Material

Electrical Resistance AT (Borealis material 6081) Sheath

Electrical Resistance Corrosion Measures

Good performance of Electrical Resistance and Corrosion Resistance

Note:

ice accretion 5MM,weed speed:30M/S